Your accredited ENC laboratory

AKUVIB is an independent accredited EMC testing laboratory for electromagnetic compatibility.

Please contact us at:
Telefon +49 (0)234 / 587 - 6000
Email emv@akuvib.de
Submit request

Through our numerous accreditations and state-of-the-art measurement technology, we cover a wide range of tests, making us your ideal partner for electromagnetic compatibility.

In our modern and accredited EMC laboratory, we offer EMC measurements according to international standards (DIN, IEC, ISO, EN, CISPR), helping you ensure and optimize the quality of your products.

Our EMC department can support you even during the development of products. AKUVIB provides tailored consulting and selection of EMC test procedures. During our measurements, we not only identify existing interferences but also work with you to develop suitable mitigation measures.

AKUVIB assists you in planning and conducting your EMC tests, keeping you informed of the test progress, and allowing you to be present during the tests on-site. In our visitor room adjacent to the EMC laboratory, you can comfortably oversee your tests and keep an eye on your components.

With extensive testing facilities, you can entrust AKUVIB with complete product validation. AKUVIB offers electromagnetic compatibility testing combined with environmental simulation and vibration testing, all under one roof. The integration of our various areas in one testing laboratory brings numerous advantages for our customers.

Radiated Emissions

  • Field strength measurements 10Hz to 6GHz

Emissions on Cables

  • Disturbance voltage measurements up to 400 MHz
  • Disturbance current measurements up to 400 MHz
  • Harmonics and flicker (three-phase up to 690 V, 75 A)

Magnetic Field Emissions

  • Magnetic fields DVC up to 400 MHz
  • Personal protection
  • (ICNIRP 1998 and 2010)

Resistance to Radiated Electric Fields

  • HF irradiation (3 m) up to 54 V/m
  • HF irradiation Automotive up to > 200 V/m (80 MHz – 6 GHz)
  • Radar pulses up to 600 V/m

Resistance to Conducted Disturbances

  • Burst impulses up to 5.5 kV and surge impulses up to 5 kV
  • Coupled disturbance voltages up to 230 MHz
  • Injected currents (BCI) up to 400 MHz
  • Test impulses for automotive electronics
  • Simulation of voltage fluctuations and power interruptions

Resistance to Magnetic Fields

  • Irradiation DC up to 1 MHz
  • Pulsed magnetic fields
  • Damped oscillating magnetic fields

Electrostatic Discharge (ESD)

  • Air discharge up to 30 kV
  • Contact discharge up to 30 kV

Other EMC Tests and Investigations

  • Power quality / Network disturbance analysis / Harmonic analysis / Long-term measurements
  • Insertion loss (s-parameters)
20170116 101451.jpg
20181031 170354.jpg
20210413 165039.jpg